Equipments Acceptance Criteria

100 KN UNIVERSAL TESTING MACHINE
  UNIVERSITY OF MALAYA
  RM 128.00 / PER-HOUR

TENSILE STRENGTH TESTING OF MATERIALS (STEEL, COMPOSITE, PLATE ETC.)

EXPECTED MAXIMUM LOAD LESS THAN 80 KN

REMARK : PRIOR DISCUSSION WITH STAFF/LECTURER IN CHARGE REQUIRED FOR NON STANDARD SPECIMENS/TEST


600 KN UNIVERSAL TESTING MACHINE
  UNIVERSITY OF MALAYA
  RM 1908.00 / PER-DAY

FLEXURAL TESTING OF BEAMS (REINFORCED CONCRETE, STEEL, TIMBER ETC.)

EXPECTED MAXIMUM LOAD LESS THAN 500 KN.

REMARK : PRIOR DISCUSSION WITH STAFF/LECTURER IN CHARGE REQUIRED FOR NON-STANDARD SPECIMENS/TEST.

CHNS ANALYZER
  UNIVERSITY OF MALAYA
  RM 700.00 / PER-SAMPLE

MENGETAHUI NISBAH CARBON, HYDROGEN, NITROGEN, SULFUR DALAM SAMPEL.

LIQUID AND SOLID


DIFFERENTIAL SCANNING CALORIMETER
  UNIVERSITY OF MALAYA
  RM 170.00 / PER-SAMPLE

DETERMINE ENDOTHERMIC AND EXOTHERMIC

SAMPLE= SOLID FORM, POWDER

SAMPLE = POWDER, SOLID FORM

WEIGHT = APPROX 10 GRAMS

FESEM
  UNIVERSITY OF MALAYA
  RM 700.00 / PER-HOUR

RESOLUTION : GEMINI®COLUMN
1.0 NM @ 15 KV
1.9 NM @ 1 KV
VALUES MEASURED AT OPTIMUM WORKING DISTANCE MAGNIFICATION: 12X- 1000 KX PROBE CURRENT : 4PA - 20NA (100NA OPTIONAL) ACCELERATION VOLTAGE : 0.1 - 30KV EMITTER : SCHOTTKY FIELD EMIITER GAS INJECTION SYSTEM : A) MULTI GIS FOR UP TO 5 PRECURSORS
B) MULTI GIS FOR UP TO 4 PRECURSORS WITH INTEGRATED LOCAL CHARGE COMPENSATION SYSTEM
C) SINGLE GIS SYSTEM FOR 1 PRECURSOR
D) FULLY AUTOMATED AND PNEUMATIC RETRACTABLE GAS INJECTOR STAGE: 6-AXIS SUPER EUCENTRIC, ALL MOTORIZED STAGE
MOTION RANGE : X,Y = 100MM
Z = 55MM, (50MM = AURIGA® 60)
Z´ = 10 MM, (13 MM = AURIGA® 60)
TILT = -10 – 60°, (-15 – 70° = AURIGA® 60) ROTATION = 360°CONTINUOUS
ANALYTICAL WORKING DISTANCE = 5 – 8.5 MM AIRLOCK: 80MM/100MM DETECTOR: SE, INLENS, BSD, STEM, FIB

DRY SAMPLE                                       PLATE MUST BE IN RANGE  (LENGTH X WIDTH ) : (<2MM X <2 MM)


FLASH POINT TESTER
  UNIVERSITY OF MALAYA
  RM 150.00 / PER-SAMPLE

MENGUKUR TITIK NYALA DARI BERBAGAI MACAM BAHAN BAKAR DAN BAHAN KIMIA. SAMPLE DALAM BENTUK CECAIR


FOUR POINT PROBE
  UNIVERSITY OF MALAYA
  RM 127.00 / PER-HOUR

TYPICALLY USED TO DETERMINE BULK RESISTIVITY

TBA


FREEZE DRYER
  UNIVERSITY OF MALAYA
  RM 39.00 / PER-HOUR

WATER REMOVAL PROCESS TYPICALLY USED TO PRESERVE PERISHABLE MATERIALS TO EXTEND SHELF LIFE OR MAKE THE MATERIAL MORE CONVENIENT FOR TRANSPORT.

ACRYLIC CHAMBER 300MM WITH 3 STEEL SHELVES.ACRYLIC PLATE BASIC ON TOP OF COOLSAFE.TEFLON COATING OF COOLSAFE.

SAMPLE FORM : SOLID


GAS CHROMATOGRAPHY
  UNIVERSITY OF MALAYA
  RM 300.00 / PER-HOUR

USED IN ANALYTICAL CHEMISTRY FOR SEPARATING AND ANALYZING COMPOUNDS THAT CAN BE VAPORIZED WITHOUT DECOMPOSITION.

LIQUID


HARDNESS TESTER
  UNIVERSITY OF MALAYA
  RM 150.00 / PER-SAMPLE

HARDNESS TEST FOR SOFT MATERIALS, PLASTIC, SOFT METAL

HRR METHOD

SOFT BEARING METALS, PLASTICS AND OTHER VERY SOFT MATERIALS.

DIMENSION=RECTANGULAR.

WIDTH=13.00MM, LENGTH=30.00MM, HEIGHT=6.00MM


HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC)
  UNIVERSITY OF MALAYA
  RM 250.00 / PER-SAMPLE

COLOUMN YANG TELAH DISEDIAKAN  :C18

TERMS AND CONDITIONS:-

  1. SAMPLE MUST NOT CONTAIN TOXIC OR HAZARDOUS MATERIAL (HARMFUL TO HEALTH). NO RADIOACTIVE SAMPLE WILL BE ACCEPTED. NO CRUDE SAMPLE WILL BE ACCEPTED AS THE PRESENCE OF COMPLEX MATRICES MIGHT CLOG THE HPLC COLUMNS.
  2. ALL SAMPLES ­MUST BE FILTERED (0.22µM) AND PREPARED INTO VIAL MORE THAN 1.0 ML VOLUME (CRYSTAL CLEAR SOLUTION). VIAL INSERT SHOULD BE USED FOR SAMPLE VOLUME <200UL.
  3. OILY AND POLYMER (OTHER THAN PEPTIDE OR FROM ACCEPTABLE SOURCES) SAMPLES ARE NOT ALLOWED.
  4. SOLVENT/BUFFER MUST BE HPLC GRADE. SUITABLE SOLVENTS INCLUDE: METHANOL, ETHANOL, ACETONITRILE AND ULTRA PURE WATER (18.2 MICRON). BELOW LISTED ARE NOT ALLOWED:
    1. NON POLAR SOLVENT EG. HEXANE, HEPTANE, DCM, CHLOROFORM & ETC.
    2. NON VOLATILE BUFFER EG. SULFATE, PHOSPHATE, BORATE & ETC.
    3. THF AND TFA ARE NOT RECOMMENDED AS THEY PROMOTE ION SUPPRESSION.
  5. THE LABORATORY WILL NOT STORE SAMPLE(S) FOR CLIENT AFTER COMPLETION OF THE SAMPLE ANALYSIS.
  6. PLEASE PROVIDE YOUR OWN CD-R OR DVD FOR DATA FILES (RAW DATA FILES, PROCESSED DATA FILES & REPORT) UPON COMPLETION OF THE SAMPLE ANALYSIS. IT WILL BE THE SOLE RESPONSIBILITY OF THE CLIENT TO KEEP THESE FILES. PENDRIVE OR HARD DISK ARE STRICTLY NOT ALLOWED.
  7. THE LABORATORY IS NOT OBLIGATED TO KEEP THE DATA FILES FOR FUTURE ANALYSIS.
  8. SHOULD THERE IS A NEED TO RE-PROCESS/RE-ANALYSE SAMPLE DATA FILE BY THE LABORATORY IN FUTURE, CLIENT HAS TO PROVIDE THE MATERIAL AND THE DATA FILES TO THE LABORATORY.
  9. PLEASE PROVIDE THE MOBILE PHASE SOLVENTS

HIGH VOLTAGE GENERATION KIT
  UNIVERSITY OF MALAYA
  RM 636.00 / PER-DAY

A HIGH VOLTAGE KIT, WHICH CAN GENERATE 3 DIFFERENT TYPES OF VOLTAGES; AC VOLTAGE (MAX. 200 KV RMS, 50 MA, 50 HZ), DC VOLTAGE (MAX. 280 KV, 10 MA) AND IMPULSE VOLTAGE (280 KV, 1.96 KJ). SUITABLE FOR MEASUREMENT OF BREAKDOWN VOLTAGE OF SOLID, LIQUID AND GAS INSULATION MATERIAL, PARTIAL DISCHARGE AND STUDIES ON LIGHTNING OVERVOLTAGE AND PROTECTIVE DEVICES IN POWER SYSTEM.

NO SAMPLES REQUIRED


ICP-OES OPTIMA 8300 SPECTROMETER
  UNIVERSITY OF MALAYA
  RM 150.00 / PER-HOUR

IT IS A TYPE OF EMISSION SPECTROSCOPY THAT USES THE INDUCTIVELY COUPLED PLASMA TO PRODUCE EXCITED ATOMS AND IONS THAT EMIT ELECTROMAGNETIC RADIATION AT WAVELENGTHS CHARACTERISTIC OF A PARTICULAR ELEMENT. THE INTENSITY OF THIS EMISSION IS INDICATIVE OF THE CONCENTRATION OF THE TRACE METALS WITHIN THE SAMPLE.

LIQUID


IMPACT TESTER
  UNIVERSITY OF MALAYA
  RM 150.00 / PER-SAMPLE

DETERMINING IMPACT STRENGHT OF PLASTIC AND CERAMIC MATERIAL UNDER CONTROLLED CONDITION

RECTANGULAR PLASTIC AND CERAMIC


INDUCTIVELY COUPLE PLASMA)
  UNIVERSITY OF MALAYA
  RM 400.00 / PER-SAMPLE

UNTUK MENGATAHUI KEPEKATAN YANG PALING RENDAH (PPM) SESUATU LOGAM BERAT (HEAVY MENTAL)

1. SAMPLE LIQUID(AQUAS)

2. SAMPLE PERLU DI 'FILTER' DAHULU DENGAN SYRINGE FILTER STANDARD SAIZ

(0.22µM) 

3. STANDARD MESTI DISEDIAKAN OLEH PENGGUNA (0.5 PPM-1000PPM)

4. TEST TIUB (50ML) UNTUK STANDARD 

5. TEST TIUB (10 ML) UNTUK SAMPLE

HARGA INI SUDAH TERMASUK HARGA GAS ARGON


MICROSCOPE 510 DSX
  UNIVERSITY OF MALAYA
  RM 100.00 / PER-HOUR

A VARIATION OF A TRADISIONAL OPTICAL MICROSCOPE THAT USES OPTICS AND A DIGITAL CAMERA TO OUTPUT AN IMAGE TO A COMPUTER 

LIQUID OR SOLID


OIL BREAKDOWN VOLTAGE TESTER
  UNIVERSITY OF MALAYA
  RM 64.00 / PER-HOUR

AN EQUIPMENT WHICH CAN MEASURE OIL BREAKDOWN STRENGTH UP TO 60 KV. COMMON TEST OBJECTS ARE MINERAL, SILICONE AND TRANSFORMER OIL.
 

MIN 1 LITRE PER OIL SAMPLE


PARTIAL DISCHARGE DETECTOR
  UNIVERSITY OF MALAYA
  RM 636.00 / PER-DAY

A MEASUREMENT SYSTEM WHICH CAN DETECT PARTIAL DISCHARGE (PD) OCCURRENCES THROUGH ELECTRICAL PULSE IN THE RANGE OF 0 TO 20 MHZ. EQUIPPED WITH PC INTERFACE AND ASSOCIATED SOFTWARE, THIS EQUIPMENT PROVIDES EASY, CONVENIENT WAY TO ANALYSE PD DATA AND PATTERNS. SUITABLE FOR DETECTING PD SIGNALS OF UP TO 60V PEAK VOLTAGE.

NO SAMPLES REQUIRED


PARTICLE SIZER
  UNIVERSITY OF MALAYA
  RM 150.00 / PER-SAMPLE

PARTICLE SIZING ON LIQUID AND POWDER

SAMPLE= LIQUID, DRY

SIZE= 0.02 MICRO - 2000 MICRO

SAMPLE = LIQUID, DRY

SIZE = 0.02 MICRO - 2000 MICRO


POTENTIOSTAT/GALVANOSTAT
  UNIVERSITY OF MALAYA
  RM 382.00 / PER-DAY

 A STATE OF THE ART INSTRUMENTATION FOR ELECTROCHEMICAL APPLICATIONS. FEATURES AVAILABLE ARE MODULARITY, IMPEDANCE ANALYSIS AND HIGH CURRENT APPLICATIONS. SUITABLE FOR MATERIAL CHARACTERISATION STUDIES, WHICH INCLUDE ELECTRICAL CONDUCTIVITY AND CHARGE AND DISCHARGE CURRENT

NO SAMPLES REQUIRED


REFRACTOMETER
  UNIVERSITY OF MALAYA
  RM 150.00 / PER-SAMPLE

UNTUK MENGUKUR KADAR / KEPEKATAN BAHAN.

-SAMPLE CECAIR


RHEOMETER
  UNIVERSITY OF MALAYA
  RM 255.00 / PER-DAY

MEASURE THE WAY IN WHICH A LIQUID,SUSPENSION OR SLURRY FLOWS IN RESPONSE TO APPLIED FORCES.

SAMPLE FORM : LIQUID

MINIMUM SAMPLE REQUIRED : 50 ML


SCANNING ELECTRON MICROSCOPE (SEM)
  UNIVERSITY OF MALAYA
  RM 200.00 / PER-HOUR

LIGHT OPTICAL MAG: 20 - 135X ELECTRON OPTICAL MAG:

RANGE 80 -130,000X

RESOLUTION:≤ 10 NM

DIGITAL ZOOM :MAX. 12X

LIGHT OPTICAL NAVIGATION CAM: COLOR

ACCELERATION VOLTAGES DEFAULT: 5 KV, 10 KV

ADVANCED MODE: ADJUSTABLE RANGE BETWEEN 4,8 KV AND 10 KV IMAGING MODE

VACUUM MODES: STANDARD MODE & CHARGE REDUCTION MODE

DETECTOR: BSD & EDS (OPTIONAL)

SAMPLE SIZE : UP TO 32 MM (Ø)

SAMPLE HEIGHT : UP TO 100 MM

SAMPLE SIZE : UP TO 32 MM (Ø)

SAMPLE HEIGHT : UP TO 100 MM

DRIED SAMPLE

SCANNING ELECTRON MICROSCOPE (SEM)
  UNIVERSITY OF MALAYA
  RM 200.00 / PER-HOUR

LIGHT OPTICAL MAG: 20 - 135X ELECTRON OPTICAL MAG:

RANGE 80 -130,000X

RESOLUTION:≤ 10 NM

DIGITAL ZOOM :MAX. 12X

LIGHT OPTICAL NAVIGATION CAM: COLOR

ACCELERATION VOLTAGES DEFAULT: 5 KV, 10 KV

ADVANCED MODE: ADJUSTABLE RANGE BETWEEN 4,8 KV AND 10 KV IMAGING MODE

VACUUM MODES: STANDARD MODE & CHARGE REDUCTION MODE

DETECTOR: BSD & EDS (OPTIONAL)

SAMPLE SIZE : UP TO 32 MM (Ø)

SAMPLE HEIGHT : UP TO 100 MM

SAMPLE SIZE : UP TO 32 MM (Ø)

SAMPLE HEIGHT : UP TO 100 MM


SOIL RESISTIVITY MEASURING EQUIPMENT
  UNIVERSITY OF MALAYA
  RM 382.00 / PER-DAY

 AN EQUIPMENT WHICH CAN MEASURE SOIL RESISTIVITY AND GROUND ELECTRODE RESISTANCE UP TO 200 KΩ. COMMON METHODS USED IN MEASUREMENT ARE WENNER AND SCHLUMBERGER METHODS

NO SAMPLES REQUIRED


SPECTROPHOTOMETER PHARO 300
  UNIVERSITY OF MALAYA
  RM 96.00 / PER-HOUR

MEASUREMENT OF ABSORBANCE, CONCENTRATION, TRANSMISSIONS, MULTI WAVELENGTHS SCAN + KINETICS IN ABSORBANCE AND TRANSMISSION MODE.

WAVELENGTH RANGE OF 190-1100NM

CUVETTE / CELL : 16MM ROUND, 10/20/50 RECTANGULAR.

SAMPLE FORM : LIQUID

PLEASE BRING YOUR OWN CUVETTE


TAN DELTA AND CAPACITANCE MEASURING EQUIPMENT
  UNIVERSITY OF MALAYA
  RM 636.00 / PER-DAY

AN EQUIPMENT WHICH CAN MEASURE THE CAPACITANCE AND TAN DELTA OF INSULATION MATERIALS UNDER VARIOUS APPLIED VOLTAGES (MAX. 280 KV). SUITABLE FOR CHARACTERISATION STUDIES ON DIELECTRIC MATERIALS. CAN BE USED SIMULTANEOUSLY WITH PD MEASURING EQUIPMENT

NO SAMPLES REQUIRED

THERMAL GRAVITY ANALYSIS (TGA)
  UNIVERSITY OF MALAYA
  RM 300.00 / PER-SAMPLE

MENGETAHUI BERAT SAMPEL YANG TERBAKAR PADA SUHU YANG BERKAITAN. MENGGUNAKAN GAS NITROGEN DAN CRUCIBLE. SUHU MAX 1000 DARJAH CELCIUS.

SOLID AND POWDER SAMPLE


UV/VIS SPECTROPHOTOMETER
  UNIVERSITY OF MALAYA
  RM 200.00 / PER-SAMPLE

SCANNING WAVE LENGHT PADA SAMPEL

SAMPLE LIQUID AND SOLID


VAPOUR PRESSURE TESTER
  UNIVERSITY OF MALAYA
  RM 150.00 / PER-SAMPLE

UNTUK MENENTUKAN TEKANAN WAP DALAM GASOLEN, SOLVENTS DAN LIGHT CRUDE OIL 


VISCOMETER (LOW VISCOSITY)
  UNIVERSITY OF MALAYA
  RM 150.00 / PER-SAMPLE

VISCOSITY MEASUREMENT FOR LOW VISCOS LIQUID

VOLUME PER TEST = 10ML

ONLY APPLY FOR LOW VISCOSITY LIQUID


X RAY DIFFRACTION (XRD) - POWDER
  UNIVERSITY OF MALAYA
  RM 100.00 / PER-HOUR

VERTICAL GONIOMETER (THETA-THETA)  

DIRECT OPTICAL ENCODING POSITIONING SYSTEM (DOPS) FOR LIFETIME GONIOMETER ACCURACY                              

MAXIMUM USABLE RANGE (DEPENDING ON ACCESSORIES) -40°< 2θ <220°                              

240 MM RADIUS, INTERFACES ARE AVAILABLE TO REDUCE THE DIFFRACTED BEAM RADIUS FOR SPECIFIC APPLICATIONS

VERY FINE POWDER 

DRIED SAMPLE


X RAY DIFFRACTION (XRD) - THIN FILM
  UNIVERSITY OF MALAYA
  RM 100.00 / PER-HOUR

VERTICAL GONIOMETER (THETA-THETA)  

DIRECT OPTICAL ENCODING POSITIONING SYSTEM (DOPS) FOR LIFETIME GONIOMETER ACCURACY                                

MAXIMUM USABLE RANGE (DEPENDING ON ACCESSORIES) -40°< 2θ <220°                              

240 MM RADIUS,

INTERFACES ARE AVAILABLE TO REDUCE THE DIFFRACTED BEAM RADIUS FOR SPECIFIC APPLICATIONS

MIN 0.1 CM                                                          

WIDTH X THICKNESS X LENGTH :2.5CM X 0.4CM X 2.5CM                                                        

DRIED SAMPLE


ZETA POTENTIAL
  UNIVERSITY OF MALAYA
  RM 250.00 / PER-SAMPLE

DETERMINING THE SURFACE CHARGE OF NANOPARTICLES IN SOLUTIONS (COLLOIDS)

SAMPLE= LIQUID

PARTICLE SIZE= NANO, NON VOLATILE, LOW VISCOSITY

SAMPLE = LIQUID

PARTICLE SIZE = NANO, NON VOLATILE, LOW VISCOSITY